PVC and TPO flat roofs, UK-wide · Mon–Fri 8am–6pm, Sat 9am–4pmFreephone 0800 088 6341
Single Ply RoofingPVC Roofing MembranesTPO and FPO Roofing MembranesMechanically Fixed Single PlyFully Adhered Single PlySingle Ply Roof ReplacementSingle Ply Roof OverlaySingle Ply Roof RepairsCommercial Single Ply RoofingSingle Ply Roofs for HomesStanding Seam Effect RoofingGreen Roof WaterproofingWarm Roof and Tapered InsulationFlat Roof Surveys and Leak Detection
West London

Hounslow warm roof insulation under single ply

A warm roof places rigid insulation above the roof deck, directly under the single ply membrane, so the structure stays warm and dry.

Hounslow sits within our West London coverage. A warm roof places rigid insulation above the roof deck, directly under the single ply membrane, so the structure stays warm and dry. Tapered insulation is cut to a slope so the same boards also create falls to the outlets.

Foil-faced insulation boards laid to falls on a flat roof with a roll of membrane ready – warm roof insulation under single ply in Hounslow

What suits roofs in Hounslow?

Roofs in Hounslow range across flat-roofed mansion blocks, mixed-use parades and tightly packed rear extensions. The town is home to about 66,000 people and is 3 miles south-west of the heart of West London. Sheltered by the city but short on working room, so material hoisting and parking suspensions are planned before a start date is set.

Work in Hounslow is designed to Approved Document L for energy, Approved Document B for fire and BS 6229 for flat roof design. In England, a refurbished flat roof is normally expected to reach about 0.16 W/m²K, which typically needs 120 to 150 mm of PIR. BS 6229 recommends designing falls at 1:40 so a finished fall of at least 1:80 is achieved after deflection and tolerances.

What is included

  • Fully sealed vapour control layer
  • U-value calculation for the proposed build-up
  • Upstand heights checked against the new roof level
  • Compliance evidence for Building Control
  • Boards bonded or mechanically fixed

Hounslow price guide

Expect a guide rate of £45–£80 per m² plus VAT in Hounslow. Larger, simpler roofs sit at the lower end.

Other services in HounslowGuide price (ex VAT)
Commercial Single Ply Roofing£90–£145 per m²
Single Ply Roofs for Homes£3,400–£5,450
Standing Seam Effect Roofing£140–£205 per m²

How to get started

After a visit to your building in Hounslow, you receive a specification, a programme and a price that will not change unless the scope does. If you manage buildings beyond Hounslow, we cover Isleworth, Heston and Richmond as well.

Call 0800 088 6341 or use the quote tool for a guide price for your Hounslow roof.

Warm Roof and Tapered Insulation in Hounslow: questions

How much does warm roof insulation under single ply cost in Hounslow?

As a guide, warm roof insulation under single ply in Hounslow costs £45–£80 per m² plus VAT. The exact figure depends on roof size, access and the condition of the existing roof, and is fixed after a survey.

Is ponding water a problem?

Standing water adds load, attracts dirt and shortens the life of details. BS 6229 expects roofs to drain, with a finished fall of at least 1:80.

What thickness of insulation does a flat roof need?

To reach around 0.16 W/m²K, most roofs need 120 to 150 mm of PIR insulation, or more with mineral wool. The exact figure comes from a U-value calculation.

What is a warm roof?

A warm roof has its insulation above the deck and below the waterproofing, so the roof structure is kept warm. It is the standard way to build and refurbish flat roofs.

More in Hounslow and nearby

Call nowGet a quote