PVC and TPO flat roofs, UK-wide · Mon–Fri 8am–6pm, Sat 9am–4pmFreephone 0800 088 6341
Single Ply RoofingPVC Roofing MembranesTPO and FPO Roofing MembranesMechanically Fixed Single PlyFully Adhered Single PlySingle Ply Roof ReplacementSingle Ply Roof OverlaySingle Ply Roof RepairsCommercial Single Ply RoofingSingle Ply Roofs for HomesStanding Seam Effect RoofingGreen Roof WaterproofingWarm Roof and Tapered InsulationFlat Roof Surveys and Leak Detection
South London

Warm Roof and Tapered Insulation in Wimbledon

A warm roof places rigid insulation above the roof deck, directly under the single ply membrane, so the structure stays warm and dry.

We install and repair warm roof insulation under single ply in Wimbledon, South London. A warm roof places rigid insulation above the roof deck, directly under the single ply membrane, so the structure stays warm and dry. Tapered insulation is cut to a slope so the same boards also create falls to the outlets.

Foil-faced insulation boards laid to falls on a flat roof with a roll of membrane ready – warm roof insulation under single ply in Wimbledon

What is included

  • Fully sealed vapour control layer
  • PIR, mineral wool or hybrid insulation to suit fire strategy
  • Upstand heights checked against the new roof level
  • U-value calculation for the proposed build-up
  • Boards bonded or mechanically fixed

What suits roofs in Wimbledon?

Wimbledon has a population of around 68,000 and lies about 5 miles west of the centre of South London. Its roofs are a mix of flat-roofed mansion blocks, mixed-use parades and tightly packed rear extensions. Tight sites mean most London roofs are loaded by hoist or crane and stripped in small sections so the building is never left open overnight.

Work in Wimbledon is designed to Approved Document L for energy, Approved Document B for fire and BS 6229 for flat roof design. In England, a refurbished flat roof is normally expected to reach about 0.16 W/m²K, which typically needs 120 to 150 mm of PIR. BS 6229 recommends designing falls at 1:40 so a finished fall of at least 1:80 is achieved after deflection and tolerances.

How much does it cost in Wimbledon?

As a guide, warm roof insulation under single ply in Wimbledon costs about £45–£75 per m² plus VAT. A survey fixes the figure for your roof.

Other services in WimbledonGuide price (ex VAT)
Single Ply Roof Repairs£320–£1,230
Fully Adhered Single Ply£125–£185 per m²
Mechanically Fixed Single Ply£110–£160 per m²

Arranging a survey in Wimbledon

Tell us about the roof, we visit Wimbledon to inspect it, and you get options with costs: repair, overlay or replacement where each is viable. If you manage buildings beyond Wimbledon, we cover Morden, Earlsfield and Tooting as well.

Speak to us on 0800 088 6341 about your Wimbledon project, or send the details through the form.

Warm Roof and Tapered Insulation in Wimbledon: questions

How much does warm roof insulation under single ply cost in Wimbledon?

As a guide, warm roof insulation under single ply in Wimbledon costs £45–£75 per m² plus VAT. The exact figure depends on roof size, access and the condition of the existing roof, and is fixed after a survey.

How much does roof insulation add to the cost?

Allow roughly £35 to £60 per m² for warm roof insulation and vapour control, more for tapered schemes with complex drainage.

What is tapered insulation?

It is insulation manufactured with a built-in slope. Laid to a scheme drawing, it creates falls on a flat deck so rainwater runs to the outlets instead of ponding.

What is a warm roof?

A warm roof has its insulation above the deck and below the waterproofing, so the roof structure is kept warm. It is the standard way to build and refurbish flat roofs.

More in Wimbledon and nearby

Call nowGet a quote