Updated 27 November 2026 · By the Single Ply Roofing team
Does re-roofing need approval?
Usually. A roof is a thermal element, so renewing more than half of it is notifiable work. Approval comes via Building Control or an installer registered with a competent person scheme.
What U-value is required?
In England a refurbished flat roof is normally expected to achieve about 0.16 W/m²K. Wales, Scotland and Northern Ireland publish their own figures.
What falls are needed?
BS 6229 recommends a design fall of 1:40 to achieve a finished fall of at least 1:80, so that the roof drains without ponding.
What fire rating applies?
Roof coverings are classified for external fire exposure. BROOF(t4) is the highest rating and allows use without restriction on distance from a boundary. The rating applies to the tested build-up, not the membrane alone.
What about condensation?
BS 5250 covers moisture control. A warm roof with a sealed vapour control layer under the insulation is the standard way to manage the risk.